Abstract

A model-based method for three-dimensional image segmentation was developed and its performance assessed in segmentation of volumetric cardiac magnetic resonance (MR) images and echocardiographic temporal image sequences. Comprehensive design of a three-dimensional (3-D) active appearance model (AAM) is reported for the first time as an involved extension of the AAM framework introduced by Cootes et al. The model’s behavior is learned from manually traced segmentation examples during an automated training stage. Information about shape and image appearance of the cardiac structures is contained in a single model. This ensures a spatially and/or temporally consistent segmentation of three-dimensional cardiac images.

The clinical potential of the 3-D AAM is demonstrated in short-axis cardiac MR images and four-chamber echocardiographic sequences. The method’s performance was assessed by comparison with manually identified independent standards in 56 clinical MR and 64 clinical echo image sequences. The AAM method showed good agreement with the independent standard using quantitative indexes of border positioning errors, endoand epicardial volumes, and left ventricular mass. In MR, the endocardial volumes, epicardial volumes, and left ventricular wall mass correlation coefficients between manual and AAM were R^2 = 0.94, 0.97, 0.82 respectively. For echocardiographic analysis, the area correlation was R^2 = 0.79. The AAM method shows high promise for successful application to MR and echocardiographic image analysis in a clinical setting.

Download

Adobe portable document format (pdf)

Copyright notice: This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. These works may not be reposted without the explicit permission of the copyright holder.

Links

IEEE Transactions on Medical Imaging

Notes

Associated labs/groups:
Department of Pediatrics, The University of Iowa
Department of Radiology, The University of Iowa

Text Reference

Steven C. Mitchell, Johan G. Bosch, Boudewijn P. F. Lelieveldt, Rob J. van der Geest, Johan H. C. Reiber, and Milan Sonka, "Active Appearance Models: Segmentation of Cardiac MR and Ultrasound Images", IEEE Transactions on Medical Imaging, September 2002, Volume 21, Issue 9, pp. 1167-1178

BibTeX Reference

@article{Mitchel_2002_IEEE_TMI,
  author = "Steven C. Mitchell, Johan G. Bosch, Boudewijn P. F. Lelieveldt, Rob J. van der Geest, Johan H. C. Reiber, and Milan Sonka",
  title = "Active Appearance Models: Segmentation of Cardiac MR and Ultrasound Images",
  journal = "IEEE Transactions on Medical Imaging",
  year = "2002",
  volume= "21",
  issue = "9",
  pages = "1167-1178"
}

The College of Engineering Imaging Group(CEIG) is part of the Department of Electrical and Computer Engineering, University of Iowa.